Proline t-mass F/I 300/500 – The thermal mass flowmeter with long-term stability and a keen sense for utility gases

The Thermal Flow Measuring Principle

Insertion flowmeter with long-term stability as remote version with up to 4 I/Os

The patented sensor design of t-mass I provides unprecedented measurement stability in thermal insertion mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. The innovative remote transmitter of t-mass I 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures measurement reliability and compliant verification.

Producto no disponible en este mercado

Selección rápida

Elija entre nuestras opciones recomendadas
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

o

Configuración individual

Continúe seleccionando entre todas las opciones posibles
  • Ventajas

    • Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof

    • High level of process control – premium measurement accuracy and repeatability

    • Reliable monitoring – detection of process disturbances and reverse flow

    • ...

  • Ámbito de aplicación

    • Measuring principle is characterized by a high operable flow range and direct mass flow measurement

    • Measurement of utility and process gases and gas mixtures in circular piping or rectangular ducts

    Device properties

    • Insertion version for DN 80 to 1500...

Características y especificaciones

Atrás

Details

  • Measuring principle

    Térmico

  • Encabezado del producto

    Insertion flowmeter with drift-free sensor as remote version with up to 4 I/Os. Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof. Measurement of utility and process gases as well as gas mixtures in circular piping or rectangular ducts.

  • Características del sensor

    High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Flexible installation – suitable for large dimensional range and circular pipes or rectangular ducts. Insertion version for DN 80 to 1500 (3 to 60"). Bidirectional measurement; high measuring performance.

  • Características del transmisor

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access.

  • Rango de diámetro nominal

    DN 80 to 1500 (3 to 60")

  • Materiales húmedos

    Materials for insertion tube
    Stainless steel, 1.4404 (316/316L)
    Process connections, process coupling
    Stainless steel, 1.4404 (316/316L)
    Sensing element
    Unidirectional
    Stainless steel, 1.4404 (316/316L)
    Alloy C22, 2.4602 (UNS N06022);
    Bidirectional
    Stainless steel, 1.4404 (316/316L)
    Reverse flow detection
    Stainless steel, 1.4404 (316/316L)
    Clamping rings
    PEEK
    PVDF
    1.4404 (316/316L)
    Flat ring seal
    EPDM
    FKM

  • Variables medidas

    Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density

  • Máx. error medido

    Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)

  • Rango de medición

    20 to 733501 kg/h (44 to 1669340 lb/h)

  • Máx. presión de proceso

    -0.5 to 20 bar_g (-7.25 to 290 psi_g)

  • Rango de temperatura del medio

    -40 °C to +180°C (-40 °F to +356°F)

  • Rango de temperatura ambiente

    -40 to 60°C (-40 to 140°F)
    Optional:
    Transmitter: -50 to 60°C (-50 to 140°F),
    Sensor: -60 to 60°C (-60 to 140°F)

  • Material de la cubierta del transmisor

    Aluminium, AlSi10Mg, coated
    Polycarbonate

  • Grado de protección

    IP66/67, Type 4X enclosure Sensor: IP68, Type 6P (optional)

  • Pantalla/Operación

    4-line backlit display with touch control (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Salidas

    4-20 mA HART (active/passive)
    4-20 mA (active/passive)
    Pulse/frequency/switch output (active/passive)
    Relay output

  • Entradas

    Status input
    4-20 mA input

  • Comunicación digital

    HART, Modbus RS485

  • Suministro de energía

    DC 24V
    AC 100 to 240V

  • Aprobaciones para áreas peligrosas

    ATEX, cCSAus, IECEx, NEPSI, JPN

  • Seguridad del producto

    CE, C-tick

  • Seguridad Funcional

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Aprobaciones y certificados metrológicos

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a

  • Certificados y aprobaciones de presión

    CRN

  • Certificados del material

    3.1 material
    NACE MR0175/MR0103

Documentos / Manuales / Software

Accesorios / Piezas de repuesto

Nr
Order code
Specification
  • 31
    • Nr 31 Order code 71323009

      Kit pow.supply,100-230VAC/24VDC, Non-haz

      Usage: Promag/Promass/Prosonic Flow/ t-mass 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.

  • 47
    • Nr 47 Order code 71323012

      Kit main elec. extender, 500 dig., Ex

      Usage: Promass/t-mass 500 digital, transmitter housing, electronic compartment.

    • Nr 47 Order code 71323013

      Kit main elec.extender,500 dig., Non-haz

      Usage: Promag/Promass/Prosonic Flow/ t-mass 500 digital, transmitter housing, electronic compartment.

  • 36
    • Nr 36 Order code 71323015

      Kit ISEM extender, 500 digital, Ex

      Usage: Promag/Promass/t-mass 500 digital, Sensor connection housing.

  • 33
    • Nr 33 Order code XPD0052-

      ISEM electr.mod., t-mass 300/500 digital

      Usage: t-mass 300/500 digital. Valid for approvals acc. feature 010. ISEM module V305-02.

  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, 100/300/400/500/500 digital

      Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.

  • 33
    • Nr 33 Order code XPD0054-

      ISEM electr.mod., t-mass 500 digital

      Usage: t-mass 500 digital. Valid for approvals acc. feature 010. ISEM module V305-00.

  • 34
  • 46
    • Nr 46 Order code 71323006

      Kit ISEM ribbon cable, 500 digital

      Usage: Promag/Promass/t-mass 500 digital, sensor connection housing.

  • 35
  • 50
  • 45
    • Nr 45 Order code 71323077

      Kit terminal option A, 500 dig., Non-haz

      Usage: transmitter housing Alu/polycarbonate, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.

    • Nr 45 Order code 71327820

      Kit terminal option C, 500 dig., Non-haz

      Usage: transmitter housing Alu/polycarbonate, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.

  • 20
    • Nr 20 Order code 71384170

      Kit cover, alu,Promag 400(C),500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF, wire with screw lock 1,5x150.

    • Nr 20 Order code 71408508

      Kit cover, polycarb., 500 digital

      Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: Cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.

  • 70
    • Nr 70 Order code 71278078

      Kit cover gasket, alu,400(C),500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF.

    • Nr 70 Order code 71278077

      Kit 10 cover gasket, polycarbonate

      Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.

  • 24
    • Nr 24 Order code 71228796

      Kit cover, remote, Alu

      Usage: Promag 400(C) = generation index C, Promag 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.

    • Nr 24 Order code 71323050

      Kit cover, remote, Alu, -50oC

      Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 FVMQ, -50oC/-58oF.

  • 73
    • Nr 73 Order code 71323051

      Kit housing gaskets, remote, Alu

      Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor.

    • Nr 73 Order code 71323052

      Kit housing gaskets, remote, Alu, -50oC

      Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.

  • 24
    • Nr 24 Order code 71323063

      Kit cover, remote, cast, Ex

      Usage: Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover cast, O-Ring 120,2x3,53 HNBR.

    • Nr 24 Order code 71323064

      Kit cover, remote, cast, -50oC, Ex

      Usage: Promass 500, Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: cover cast, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.

  • 73
    • Nr 73 Order code 71323065

      Kit housing gaskets, remote, cast, Ex

      Usage: Promass 500, Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 120,2x3,53 HNBR for cover, O-Ring 88,50x3,53HNBR for housing/sensor

    • Nr 73 Order code 71323066

      Kit housing gaskets,remote,cast,-50oC,Ex

      Usage: Promass 500, Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 120,2x3,53 FVMQ for cover, -50oC/-58oF, O-Ring 88,50x3,53 FVMQ for hous./sensor, -50oC/-58oF.

  • 13
    • Nr 13 Order code 71276494

      Kit securing clamp, screw

      Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital. Consists of: cover clamp, screw M4x16.

  • 82
    • Nr 82 Order code 71228792

      Kit display protec., 400(C)/500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: display protection 1.4301, installation material.

  • 87
    • Nr 87 Order code 71343504

      Kit weather protection cover,500 digital

      Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing. Consists of: weather protection cover 4404.

    • Order code 71346427

      Pipe Mounting kit Transmitter 500digital

    • Order code 71351317

      Kit wireless antenna extended range

      Consists of: Connection cable in the transmitter, Ex cable entry for antenna, 1.5m cable, antenna, angle with union nut.

    • Order code 6X5BXX-

      Transmitter t-mass 500, 6X5BXX

      With an integrated web server.

    • Order code DK6012-

      t-mass 500, sensor cable set

      Connection Cable (analog and digital) between Sensor Junction Housing and Transmitter for Remote Devices of Proline 500.

    • Order code DK6ML-

      Cold tap, atmospheric pressure, t-mass

      Usage: t-mass 65I, 6BAB, 6TAB, 6I3B, 6I5B. For insertion version. For mounting and extracting the device at atmospheric pressure. Min. insertion length: 335mm (13in).

    • Order code DK6003-

      Hot tap, process pressure, 300/500

      Usage: t-mass 6I3B, 6I5B Insertion and withdrawal of sensor under pressure without process interruption.

    • Order code DK6004-

      Plate conditioner 35 hole, t-mass

      Usage: t-mass I 300/500 -200oC...+400oC / -330...+750oF

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.