Producto no disponible en este mercado
Resumen de especificaciones
-
Variables medidas
Concentración
Presión en la celda
Temperatura en la celda -
Homologaciones para áreas de peligro
ATEX zona 2
Ámbito de aplicación
The SS2100a gas analyzer measures accurate trace gas components (H2O, CO2, H2S, NH3, and C2H2) in natural gas and hydrocarbon processing applications using tunable diode laser absorption spectroscopy (TDLAS) technology. It requires little maintenance and does not need recalibration or periodic replacement parts. The SS2100a is certified for ATEX Zone 2.
Gas analysis: ppb level measurement of H2O & NH3, ppm level measurement of H2O, H2S, CO2, NH3, and C2H2, and % level measurement of H2S and CO2
Natural gas: production, storage, transportation, distribution
Refinery: hydrogen recycle, catalytic reforming, flaring, cracking
Gas processing: fractionation, sour/acid gas removal
LNG: liquefication, custody transfer
Petrochemical: cracking, acetylene converter, caustic wash tower
Biomethane: H2O and H2S quality measurements
Ventajas
Accurate, real-time measurements
Low cost of ownership; no consumables; virtually maintenance free and reliable in harsh environments
Measurements not hampered by wet-up (absorption) or dry-down (desorption)
Dependable with greater repeatability than surface-based sensors
Analog and serial outputs for remote monitoring
Available for the following measurements: H2O, CO2, H2S, NH3, C2H2
ATEX Zone 2 certified
Gama Xpert
-
Productos especializados
- Diseñados para aplicaciones exigentes
Excelencia técnica
Simplicidad
Variable
-
Productos estándar
- Seguros, resistentes y con poco mantenimiento
Excelencia técnica
Simplicidad
-
Productos de alta gama
- Altamente funcionales y prácticos
Excelencia técnica
Simplicidad
-
Productos especializados
- Diseñados para aplicaciones exigentes
Excelencia técnica
Simplicidad
Variable
Gamas FLEX | Excelencia técnica | Simplicidad |
---|---|---|
Gama Fundamental Satisfaga sus necesidades básicas de medición |
Excelencia técnica
|
Simplicidad
|
Gama Lean Maneje los principales procesos fácilmente |
Excelencia técnica
|
Simplicidad
|
Gama Extended Optimice sus procesos con tecnologías innovadoras |
Excelencia técnica
|
Simplicidad
|
Gama Xpert Domine las aplicaciones más exigentes |
Excelencia técnica
|
Simplicidad
Variable |
-
-
Información técnica (TI)
SS2100a TDLAS Gas Analyzer
System design and specification for the SS2100a TDLAS Gas Analyzer
Idioma:
Inglés
Versión:
01/11/2021
Tamaño del archivo:
355.1 KB
Nombre del archivo:
TI01668CEN_01.21.pdf
-
-
-
Manual de instrucciones (BA)
SS2100a TDLAS Gas Analyzer Operating Instructions
Commission, operation and maintenance details for the
SS2100a TDLAS Gas AnalyzerEN ES 28/08/2021Idioma:
Inglés
Versión:
28/08/2021
Tamaño del archivo:
13.7 MB
Nombre del archivo:
BA02163CEN_01.21.pdf
-
-
-
Manual de instrucciones (BA)
TDLAS Gas Analyzer Sample Cells
Operation and maintenance details for TDLAS Gas Analyzer
sample cellsIdioma:
Inglés
Versión:
04/10/2021
Tamaño del archivo:
2.8 MB
Nombre del archivo:
BA02188CEN_01.21.pdf
-
-
-
Manual de instrucciones (BA)
SS2100-series Sample Conditioning System Operating Instructions
Commission, operation, and maintenance details for the
SS2100-series Sample Conditioning SystemIdioma:
Inglés
Versión:
21/02/2024
Tamaño del archivo:
1.3 MB
Nombre del archivo:
BA02337CEN_0123.pdf
-
-
-
Parámetro del equipo (GP)
Descripción de los parámetros del equipo Firmware FS 5.16
Descripción denivel experto e información operativa
para los parámetros del dispositivoEN ES 23/04/202217/09/2021Idioma:
Español
Versión:
23/04/2022
Tamaño del archivo:
6.1 MB
Nombre del archivo:
GP01177CES_01.21.pdf
-
-
-
Parámetro del equipo (GP)
Device Parameters (NS 5.14)
Expert-level description and operational information for
device parametersIdioma:
Inglés
Versión:
17/09/2021
Tamaño del archivo:
4.8 MB
Nombre del archivo:
GP01180CEN_01.21.pdf
-
-
-
Instrucciones de instalación (EA)
Measurement Cell Mirror Cleaning Instruction
Instructions for cleaning the 0.1 m, 0.8m,
8/28 m measurement cell mirror for multiple
product platformsIdioma:
Inglés
Versión:
28/08/2021
Tamaño del archivo:
193 KB
Nombre del archivo:
EA01381CEN_01.21.pdf
-
-
-
Instrucciones de seguridad Ex (XA)
SS2100a TDLAS Gas Analyzer Safety Instructions
Safety Instructions for the SS2100a TDLAS Gas Analyzer
Idioma:
Inglés
Versión:
02/11/2021
Tamaño del archivo:
1.3 MB
Nombre del archivo:
XA02782CEN_01.21.pdf
-
-
-
Documentación especial (SD)
AMS100 Software Operating Instruction
Instructions for operating the AMS100 software as an
alternative method for TDLAS gas analyzer system configurationIdioma:
Inglés
Versión:
10/05/2023
Tamaño del archivo:
1.3 MB
Nombre del archivo:
SD02863CEN_0223.pdf
-
-
-
PU (publicación)
TDLAS and QF analyzers application guide - Accurate and reliable measurement of H2O, H2S, CO2, C2H2, NH3, and O2
A guide to TDLAS and QF technology application notes (natural gas,
hydrogen, biomethane, carbon capture, LNG, gas processing, NGL
fractionation, petrochemical, syngas, ammonia, and refining) for the
oil & gas and chemical industries (relating to J22, JT33, SS500, SS2100,
SS2100a, SS2100i, and OXY5500 analyzers).Idioma:
Inglés
Versión:
27/11/2023
Tamaño del archivo:
4.1 MB
Nombre del archivo:
PU01459CEN_0323.pdf
-
-
-
PU (publicación)
Factory acceptance test (FAT) information - For TDLAS and QF analyzers
An overview about the factory acceptance tests (FATs) offered for
TDLAS and QF analyzers (SS2100, SS2100i, SS2100a, J22, JT33,
SS500, OXY5500) to customers.Idioma:
Inglés
Versión:
16/10/2023
Tamaño del archivo:
1.2 MB
Nombre del archivo:
PU01544CEN_0123.pdf
-
-
-
PU (publicación)
Approval drawings - For TDLAS and QF analyzers
An overview about the engineered approval drawings offered
for TDLAS and QF analyzers (SS2100, SS2100i, SS2100a,
J22, JT33, OXY5500, SS500) to enable customers to confirm
that the system fabrication meets their approval.Idioma:
Inglés
Versión:
22/08/2022
Tamaño del archivo:
357.9 KB
Nombre del archivo:
PU01488CEN_0122.pdf
-
-
-
Innovación (IN)
TDLAS analyzers for refinery gases - Accurate and reliable measurement of H2S and H2O
An overview brochure of our tunable diode laser spectroscopy
(TDLAS) gas analyzers (including the JT33, SS2100, SS2100i,
and SS2100a TDLAS gas analyzers) to measure water /
moisture (H2O) and hydrogen sulfide (H2S) in the refining
industry segment of the chemical industry /
Oil & Gas industry using SpectraSensors technology.Idioma:
Inglés
Versión:
31/10/2023
Tamaño del archivo:
8.7 MB
Nombre del archivo:
IN01234CEN_0223.pdf
-
-
-
Innovación (IN)
TDLAS analyzers for olefins production - Accurate and reliable measurement of C2H2, NH3, H2O, H2S, and CO2
An overview brochure of our tunable diode laser absorption
spectroscopy (TDLAS) gas analyzers (including the JT33, SS2100,
SS2100i, and SS2100a TDLAS gas analyzers) to measure
acetylene (C2H2), ammonia (NH3), water / moisture (H2O),
hydrogen sulfide (H2S), and carbon dioxide (CO2) in the
olefins / chemical industry using SpectraSensors technology.Idioma:
Inglés
Versión:
31/10/2023
Tamaño del archivo:
8.7 MB
Nombre del archivo:
IN01232CEN_0223.pdf
-
-
-
Innovación (IN)
TDLAS, QF 가스 분석기 가이드
측정 원리, 구성 및 인증 정보
Idioma:
Coreano
Versión:
20/02/2023
Tamaño del archivo:
1.4 MB
Nombre del archivo:
IN01235C66KO.pdf
-
-
-
Innovación (IN)
정유 가스 공정에서의 TDLAS 가스 분석기
정확하고 신뢰성 있는 황화수소(H2S) 및 수분(H2O) 측정
Idioma:
Coreano
Versión:
20/02/2023
Tamaño del archivo:
4.2 MB
Nombre del archivo:
IN01234C66KO.pdf
-
-
-
Innovación (IN)
TDLASおよびQFアナライザ技術ガイド - 動作原理、装置構成、認証情報
波長可変半導体レーザー吸光分光(TDLAS)および蛍光消光(QF)アナライザの製
Idioma:
Japonés
Versión:
13/05/2024
Tamaño del archivo:
6.1 MB
Nombre del archivo:
IN01235CJA_0623_TDLAS_QF_Analyzer_Guide.pdf
-
-
-
Innovación (IN)
Guide technologique des analyseurs TDLAS et QF
Principe de fonctionnement, configurations et informations
de certificationIdioma:
French
Versión:
09/01/2024
Tamaño del archivo:
815.6 KB
Nombre del archivo:
IN01235CFR - TDLAS et QF.pdf
-
-
-
Innovación (IN)
TDLAS and QF analyzers technology guide - Principle of operation, configurations, and certification information
A technology guide examining our tunable diode laser absorption
spectroscopy (TDLAS) and quenched fluorescence (QF) analyzer
portfolio (including the J22, JT33, SS500, SS2100, SS2100i, and SS2100a
TDLAS gas analyzers, and the OXY5500 precision oxygen analyzer) to
measure water / moisture (H2O), hydrogen sulfide (H2S), carbon
dioxide (CO2), oxygen (O2), ammonia (NH3), and acetylene (C2H2) in
natural gas process streams within the chemical industry / Oil & Gas
industry using SpectraSensors technology.Idioma:
Inglés
Versión:
27/11/2023
Tamaño del archivo:
4.3 MB
Nombre del archivo:
IN01235CEN_0623.pdf
-
-
-
Innovación (IN)
TDLAS analyzers for natural gas processing - Accurate and reliable measurement of H2O, H2S, and CO2
An overview brochure of our tunable laser diode absorption
spectroscopy (TDLAS) gas analyzers (including the J22, JT33,
SS2100, SS2100i, and SS2100a) to measure water / moisture (H2O),
hydrogen sulfide (H2S), and carbon dioxide (CO2) in the natural gas
processing segment of the Oil & Gas industry using SpectraSensors
technology.Idioma:
Inglés
Versión:
27/11/2023
Tamaño del archivo:
3 MB
Nombre del archivo:
IN01233CEN_0223.pdf
-
-
-
Innovación (IN)
Optical analysis technologies for LNG - Reliable, real-time TDLAS and Raman measurement
A portfolio overview brochure about our TDLAS and Raman
spectroscopy analyzer systems for the LNG / Oil & Gas industry
(includes the SS2100, SS2100i, SS2100a, J22, JT33, Raman Rxn4
and Raman Rxn5 analyzers, and the Raman Rxn-41 probe).Idioma:
Inglés
Versión:
27/11/2023
Tamaño del archivo:
12.2 MB
Nombre del archivo:
IN01281CEN_0223.pdf
-
-
-
Innovación (IN)
올레핀 생산 공정에서의 TDLAS 가스 분석
정확하고 신뢰성 있는 아세틸렌(C2H2), 암모니아(NH3), 수분(H2O), 황화수소(H2S), 이산화탄소(CO2) 측정
Idioma:
Coreano
Versión:
20/02/2023
Tamaño del archivo:
1.6 MB
Nombre del archivo:
IN01232C66KO.pdf
-
-
-
AI (nota de aplicación)
Natural gas processing: H2O in molecular sieve dryer vessel outlet
This application note explains the use of TDLAS technology
to measure H2O from molecular sieve dryer vessel
outlets in natural gas production.Idioma:
Inglés
Versión:
13/09/2021
Tamaño del archivo:
294 KB
Nombre del archivo:
AI01219CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Natural gas processing: H2S in propane NGL fractionation
This application note discusses the use of TDLAS to measure hydrogen
sulfide in propane.Idioma:
Inglés
Versión:
28/09/2021
Tamaño del archivo:
205.9 KB
Nombre del archivo:
AI01247CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Natural gas processing: H2O in propane, NGL fractionation
This application note discusses the use of TDLAS as a highly selective
and accurate method for water measurement in propane.Idioma:
Inglés
Versión:
28/09/2021
Tamaño del archivo:
216.6 KB
Nombre del archivo:
AI01242CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Natural gas processing: H2O in ethane/propane mix, NGL fractionation
This application note discusses the use of TDLAS as a highly selective
and accurate method for water measurement in a propane and
ethane mix.Idioma:
Inglés
Versión:
28/09/2021
Tamaño del archivo:
207.7 KB
Nombre del archivo:
AI01243CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Natural gas processing: H2O in ethane, NGL fractionation
This application note discusses the use of TDLAS as a highly selective
and accurate method for water measurement in ethane.Idioma:
Inglés
Versión:
28/09/2021
Tamaño del archivo:
205.6 KB
Nombre del archivo:
AI01244CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Natural gas processing: H2S in Y-grade NGL fractionation
This applicationnote discusses the use of TDLAS to measure hydrogen
sulfide in Y-grade feed to NGL fractionation units.Idioma:
Inglés
Versión:
28/09/2021
Tamaño del archivo:
206.7 KB
Nombre del archivo:
AI01250CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Petrochem: NH3 in pure propylene
This application note examines the use of TDLAS to measure ammonia
concentration in pure propylene.Idioma:
Inglés
Versión:
12/10/2021
Tamaño del archivo:
207.2 KB
Nombre del archivo:
AI01261CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Petrochem: H2O in pure ethylene
This application note examines the use ofTDLAS to measure water
concentration in pure ethylene.Idioma:
Inglés
Versión:
12/10/2021
Tamaño del archivo:
189.3 KB
Nombre del archivo:
AI01259CEN_0121.pdf
-
-
-
AI (nota de aplicación)
H2O in continuous catalytic reformer H2 recycle streams
This application note studies the use of TDLAS to measure H2O in
continuous catalytic reformer H2 recycle steams in refining.Idioma:
Inglés
Versión:
19/10/2021
Tamaño del archivo:
185.8 KB
Nombre del archivo:
AI01275CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Refining: H2S in flare gas
This application note studies the use of TDLASto measure H2S in
refinery flare gas.Idioma:
Inglés
Versión:
19/10/2021
Tamaño del archivo:
199 KB
Nombre del archivo:
AI01277CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Refining: H2S in fuel gas
This application note studies the use of TDLAS to measure H2S in
refinery fuel gas.Idioma:
Inglés
Versión:
19/10/2021
Tamaño del archivo:
201.5 KB
Nombre del archivo:
AI01278CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Refining: H2O in propane/propylene mix
This application note studies the use of TDLAS to measure H2O in
in propane/propylene mixtures in refineries.Idioma:
Inglés
Versión:
19/10/2021
Tamaño del archivo:
227 KB
Nombre del archivo:
AI01279CEN_0121.pdf
-
-
-
AI (nota de aplicación)
H2S in continuous catalytic reformer hydrogen recycle streams
This application note studies the use of TDLAS to measure H2S in
continuous catalytic reformer H2 recycle steams in refining.Idioma:
Inglés
Versión:
19/10/2021
Tamaño del archivo:
188.3 KB
Nombre del archivo:
AI01281CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Refining: H2O in alkylation feedstock
This application note studies the use of TDLAS to measure H2O in
olefin feedstock in refinery HF alkylation units.Idioma:
Inglés
Versión:
19/10/2021
Tamaño del archivo:
215.2 KB
Nombre del archivo:
AI01282CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Refining: H2O in n-butane feed gas to UOP Butamer process
This application note studies the use of TDLAS to measure H2O in
n-butane feed gas to UOP Butamer process reactors.Idioma:
Inglés
Versión:
19/10/2021
Tamaño del archivo:
186.8 KB
Nombre del archivo:
AI01283CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Petrochem and refining: H2O in instrument air
This application note studies the use of TDLAS to measure moisture in
instrument air systems during refining.Idioma:
Inglés
Versión:
19/10/2021
Tamaño del archivo:
216.9 KB
Nombre del archivo:
AI01284CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Petrochem: C2H2 in mid-bed of back end acetylene converters
This application note discusses the use of TDLAS to
measure acetylene concentration in the mid bed of
back end acetylene converters.Idioma:
Inglés
Versión:
26/10/2021
Tamaño del archivo:
206.4 KB
Nombre del archivo:
AI01285CEN_0121.pdf
-
-
-
AI (nota de aplicación)
Petrochem: C2H2 in outlet of back end acetylene converters
This application note discusses the use of TDLAS to measure
acetylene concentration at the outlet of back end
acetylene converters.Idioma:
Inglés
Versión:
26/10/2021
Tamaño del archivo:
205.2 KB
Nombre del archivo:
AI01286CEN_0121.pdf
-