Deltabar S FMD76
Este producto ya no se encuentra disponible.
Consulte la nueva generación en la sección predecesor / sucesor o contacte con su entidad local de Endress+Hauser.
Documentos / Manuales / Software
-
Deltabar S
PMD75, FMD77, FMD78
Differential pressure measurement and pressure measurement
Technical Information (TI) -
Cerabar S / Deltabar S / Deltapilot S
HART V02.30.zz
Description of Instrument Functions
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterManual de instrucciones (BA) -
Deltabar S FMD77/78; PMD75
PROFIBUS PA (V 04.01.zz)
Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communication via
PROFIBUS PAManual de instrucciones (BA) -
Cerabar S /Deltabar S /Deltapilot S
Description of device
functions
PROFIBUS PA
V04.01.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterManual de instrucciones (BA) -
Deltabar S FMD77, FMD78, PMD75
HART V02.30.zz
Operating Instructions
Differential pressure transmitter with metal sensors
Manual de instrucciones (BA) -
Cerabar S / Deltabar S / Deltapilot S, Description of device functions
FOUNDATION Fieldbus
V 04.00.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterManual de instrucciones (BA) -
Deltabar S FMD77/78; PMD75
FOUNDATION Fieldbus (V 04.00.zz)
Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
FOUNDATION FieldbusManual de instrucciones (BA) -
Cerabar S, Deltabar S, Deltapilot S
Cerabar S, Deltabar S, Deltapilot S
Process pressure measurement/differntial pressure
measurement/hydrostatic level measurement
V 04.00.zzShort Instruction (KA)12/14Alemán , Inglés -
Cerabar S, Deltabar S, Deltapilot S
Cearabar S - pressure transmitter
Deltabar S - differential
pressure transmitter
Deltapilot S - hydrostatic transmitterShort Instruction (KA)12/14Alemán , Inglés -
Deltabar S FMD77/78; PMD75
Brief Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
FOUNDATION FieldbusShort Instruction (KA)04/17Inglés -
Deltabar S FMD77/78; PMD75
Brief Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
PROFIBUS PAShort Instruction (KA)04/17Inglés -
Exchange of electronics on Cerabar S, Deltabar S, and Deltapilot S
Austausch der Elektronik am Cerabar S, Deltabar S, Deltapilot S
Exchange of electronics on Cerabar S, Deltabar S, and Deltapilot S
FMB70-, FMD72-, FMD76-, FMD77-, FMD78-, PMC71-, PMD70-, PMD75-,
PMP71-, PMP72-, PMP75-Short Instruction (KA)04/12Alemán , Inglés -
Deltabar S FMD77, FMD78, PMD75
HART
Brief Operating Instructions
Differential pressure transmitter with metal sensors
Short Instruction (KA)03/18Inglés -
Cerabar S, Deltabar S, Deltapilot S
Cearabar S - pressure transmitter
Deltabar S - differential pressure transmitter
Deltapilot S - hydrostatic level measurement
V02.30.zzShort Instruction (KA)02/18Alemán , Inglés -
Aluminum housing T14
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Feed-through and adapter for T15
Installation Instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Push button housing
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Display
Installation Instruction
Cerabar S, Deltabar, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Mounting set for housing T14/15
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Harting plug HAN7D
Installation instruction
Cerabar M/S, Deltabar M/S, Deltapilot M/S
Installation Instructions (EA) -
Aluminum housing T15
Installation instruction
Deltabar S, Deltapilot S
Installation Instructions (EA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
FM Control Drawing
XA01064P-B
NIEx Safety Instructions (XA) -
Safety Instructions
Deltabar S FMD76
II 1/2 D Ex ia IIIC T85 °C Da/Db
KEMA 03 ATEX 1561Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 G Ex ia IIC T6 ... T4 Ga/Gb
IECEx:
Ex ia IIC T6...T4 Ga/Gb
Instrucciones de seguridad
Transmisor de presión diferencial
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77/78
CSA Control Drawing
960006697 I
ISEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1 G Ex ia IIC T6...T4 Ga
II 1 D Ex ia IIIC T85°C Da
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Ex ia IIC T6...T4 Ga/Gb
IECEx KEM06.0011Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T4/T6 Ga/GbEx Safety Instructions (XA) -
Cerabar S PMC71, PMP71, PMP75
Deltabar S FMD77, FMD78, PMD75
CSA Control Drawing
960006717 G
ISEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
II 1/2 D Ex ia IIIC T85°C Da/Db
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T6...T4 Ga/Gb
TÜV 13.2007 (INMETRO)Ex Safety Instructions (XA) -
Deltabar S FMD76
KEMA 03 ATEX 1561
II 1/2 D
Protection: Ex iaD 20 IP67 T85°CEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex nA IIC T6 Gc
GYJ14.1447 (NEPSI)Ex Safety Instructions (XA) -
Safety Instructions
Cerabar S PMC71, PMP71, PMP72, PMP75
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM Control Drawing
960006703 E
ISEx Safety Instructions (XA) -
Safety Instructions
Deltabar S FMD76
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIIC T85 °C Da/Db
TÜV 13.2007 (INMETRO)Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 3 G Ex nA IIC T6 Gc
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
FM Control Drawing
960006696 F
IS, NI, DIPEx Safety Instructions (XA) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
Allgemeine bauaufsichtliche Zulassung Z-65.11-384
Certificate (ZE) -
RFID TAG
Certificate/Declaration of Conformity
ATEX:
II 2 G Ex ia IIC T6 Gb
II 2 D Ex ia IIIC T80°C Db;
IECEx:
Ex ia IIC T6 Gb
Ex ia IIIC T80°C Db
IECEx EPS 15.0042X; EPS 15 ATEX 1 1011 XCertificate (ZE) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960534-2092 B
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
FM
Drawing No.: 960006703 C
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960534-2092 D
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
FM
Drawing No.: 960006703 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM
Drawing No.: 960534-1092 B
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
CSA
Drawing No.: 960006717 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP75, FMD76, FMD77, FMD78, PMD70,
PMD75
CSA
Drawing No.: 960006717 D
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960006697 E
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
CSA
Drawing No.: 960006717 C
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM
Drawing No.: 960534-1092 D
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Interoperability Statement: Deltabar S (Evolution), FOUNDATION fieldbus
Endress+Hauser field device has been tested with Rockwell Automation
Integrated Architecture-based host system Allen-Bradley ControlLogix.
Deltabar S (Evolution), FOUNDATION fieldbus Pressure Transmitter, Device
Revision: 5, DD Revision: 1, Device ID: 0x1009, Software Revision: 2.00Special Documentation (SD) -
Deltabar S PMD70/75, FMD76/77/78
Functional Safety data sheet / Datenblatt zur Funktionalen Sicherheit
Special Documentation (SD) -
Functional Safety Manual
Deltabar S PMD75, FMD77, FMD78
Pressure and Differential Pressure, Level and Flow Measurement
with Output Signal 4...20 mASpecial Documentation (SD) -
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Cerabar S PMC71, PMP71, PMP75
Manufacturer Information for users regarding software updates (NE53)
Software version 02.10.40
Manufacturer Information (MI) -
Cerabar S PMC71, PMP71, PMP75,
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Manufacturer Information for users regarding softwareupdates (NE53)
Software version V03.00.00 / DevRev 6 FOUNDATION FIELDBUS
Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Cerabar S PMC71, PMP71, PMP75
Manufacturer Information for users regarding software updates (NE53)
Software version V4.00.10 PROFIBUS PA
Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding software updates (NE53)
Software version V04.00.01 FF
Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding softwareupdates (NE53)
Software version V04.01.00 PA
Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding software updates (NE53)
Software version V02.11.00 HART
Manufacturer Information (MI) -
Control Engineering marzec 2006
Akredytowana kalibracja przetworników ci&
347;nienia i ró
&
380;nicy ci&
347;nie&
324;Publications (PU)09/08Polaco -
Nap&
281;dy i Sterowanie marzec 2007
Akredytowana kalibracja przetworników
ci&
347;nienia i ró&
380;nicy ci&
347;nie&
324;Publications (PU)08/09Polaco -
Pomiary ciśnień PAR_09_2010
Specjalista z firmy Endress+Hauser podpowiada, w jaki
sposób można uniknąć najczęstszych problemów z pomiarami różnicy
ciśnień.Publications (PU)03/12Polaco -
Pomiary ciśnień ECiZ_10_2011
Specjalista z firmy Endress+Hauser podpowiada, w jaki
sposób można uniknąć najczęstszych problemów z pomiarami różnicy
ciśnień.Publications (PU)03/12Polaco -
压力测量
用于过程压力、差压、液位和流量测量的专业仪表
Fields of Activities (FA)09/15Chino -
Basınç Ölçümü
Proses basıncı, fark basınç, seviye ve akış için güçlü enstrümanlar
Fields of Activities (FA)05/15Turco -
Mesure de pression
Appareils de mesure pour la pression de process, la pression
différentielle, le niveau et le débitFields of Activities (FA)03/17fr -
Druckmesstechnik
Leistungsfähige Messgeräte für Prozessdruck, Differenzdruck, Füllstand
und DurchflussFields of Activities (FA)03/17Alemán -
Misura della pressione
Potenti strumenti per la misura della pressione di processo, pressione
differenziale,
livello e portataFields of Activities (FA)03/17Italiano -
Pressure measurement
American version: Powerful instruments for process pressure,
differential pressure, level
and flowFields of Activities (FA)03/17Inglés -
Pressure measurement
Powerful instruments for process pressure, differential pressure, level
and flowFields of Activities (FA)03/17Inglés -
Catálogo Medición de Presión
Instrumentos para la medición de presión, presión diferencial, nivel y
caudal de procesoFields of Activities (FA)03/17Español -
Pomiar ciśnienia
Potężna aparatura do pomiaru
ciśnienia procesowego, różnicy
ciśnień, poziomu i przepływuFields of Activities (FA)03/14Polaco -
Komplettpaket Druckmesstechnik
Ein Ansprechpartner - spart Zeit und reduziert Kosten
Competence Brochure (CP)05/15Alemán -
Deltabar S Differential Pressure Transmitter via
FOUNDATION fieldbus to the PlantPAx Process Automation System
System using a 1757-FFLD or FFLDC
Integration DocumentSystem Partner (SP)03/12Inglés -
Deltabar S Transmitter via PROFIBUS PA to the PlantPAx Process
Automation System
System using a 1788HP-EN2PAR Linking Device
Integration DocumentSystem Partner (SP)01/13Inglés -
Deltabar S Transmitter via HART to the PlantPAx Process Automation
System
System using a ControlLogix 1756 HART Analog Input Module
Integration DocumentSystem Partner (SP)01/09Inglés -
GSD Single, GSD_EH_PA_PR_Deltabar_0x1542_V03_00_10_PALIB, 14.04.2014 (Pre
ssure, Deltabar S, 0x1542)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)3.00.10Language neutral -
GSD Single, GSD_EH_PA_PR_DeltabarS_0x1542_0x03_0x01_PALIB, 19.05.2014 (Pr
essure, Deltabar S, 0x1542)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x06_0x03_FFLIB_ITK5_20, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.20Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x01_0x01, 04.01.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x16_0x03, 28.05.2015 (Pressure, Deltabar S)
HART,
PDM Version: 6.1, 8.1, 8.2.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x15_0x04, 31.03.2014 (Pressure,
Deltabar S, 0x0017)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.0, 10.1, 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x14_0x02, 27.02.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_PR_DeltabarS_0x0017_0x15_0x04, 21.08.2019 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x17_0x01, 23.04.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x03_0x02, 17.08.2015 (Pressure, Deltabar S)
PROFIBUS PA,
PDM Version: 6.0 SP5, 6.1, 8.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_PR_DeltabarS_0x0017_0x15_0x04, 21.08.2019 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x01_0x02, 04.01.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
PDM Version: 6.0 SP3, 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x05_0x01_FFLIB_ITK4_60, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.60Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x06_0x01_FFLIB_ITK5_01, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.01Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_0_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_5_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Other, EDD_FF_PR_DeltabarS_0x1009b_0x07_0x02, 12.05.2014 (Pressure, D
eltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 10.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x0A_0x01, 06.11.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x05_0x01_FFLIB_ITK4_61, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.61Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x15_0x07, 25.02.2015 (Pressure,
Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5, 6.1, 8.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, DeltabarS_xMD7x_FF_FW4_00_zz_Dev_Rev_7, 22.10.2020 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltabarS_PMx7x_FF_V3_00_xx_DevRev6, 22.10.2020 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltabarS_xMD7x_PA_FW4_01_zz_Dev_Rev_3, 21.10.2020 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, DeltabarS_xMD7x_PA_V03_00_10, 21.10.2020 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltabarS_xMD7x_PA_V4_00_xx, 21.10.2020 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltabarS_xMD7x_HART_FW_2_30_zz_Dev_Rev_23, 26.10.2020 (Pressure, Deltabar S, 0x0017)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0 SP4
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.4.189.51Language neutral -
DTM Single, DeltabarS_xMD7x_HART_FW2_20_zz_Dev_Rev_22, 26.10.2020 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11, R3.12Device Type Manager (DTM)1.4.189.51Language neutral -
DTM Single, DeltabarS_xMD7x_V02_00, 23.10.2020 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, DeltabarS_xMD7x_V02_10_xx, 23.10.2020 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, DeltabarS_xMD7x_V01_00, 23.10.2020 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_FF_Package_Pressure_1_05_00, 29.05.2018 (Pressure)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02Placa frontal1.05.00Language neutral -
Faceplate Single, PRM_FF_PR_DeltabarS_0x1009b_0x07_0x02, 07.04.2014 (Pres
sure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.11Placa frontal1.00.00Language neutral -
Faceplate Single, PRM_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Plant Resource Manager Version: R3.31Placa frontal1.00.00Language neutral -
Faceplate Single, PRM_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Plant Resource Manager Version: R3.12Placa frontal1.00.00Language neutral -
Cerabar, Cerabar S, Deltabar S
Código de producto: FMD76-, FMD77-, FMD78-, PMC71-, PMC71B-, PMD70-, PMD75-, PMP51B-, PMP71-, PMP71B-, PMP72-, PMP75-
Número Declaración: HE_01332_01.20
Especificaciones del fabricante: Performance characteristicsManufacturer DeclarationAlemán , Inglés -
Cerabar S, Deltabar S, Deltapilot S
Código de producto: FMB70-, FMD76-, FMD77-, FMD78-, PMC71-, PMD70-, PMD75-, PMP71-, PMP72-, PMP75-
Número Declaración: HE_00729_01.17Manufacturer DeclarationAlemán , Inglés -
Deltabar S
Código de producto: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
EU DeclarationAlemán , Inglés , fr -
Deltabar S
Código de producto: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Región: China
Entidad certificadora: ACMA
Número de certificado: EC11012AMiscellaneousInglés -
Cerabar S, Deltabar M, Deltabar S
Código de producto: PMP75-, PMP72-, PMP71-, PMD75-, PMD70-, PMD55-, PMC71-, FMD78-, FMD77-, FMD76-
Región: Russia (TR CU)
Entidad certificadora: EAC
Protección: Ex d, Ex ia, Ex iaD 20, Ex taExplosion ProtectionRuso -
Deltabar S
Código de producto: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Región: China
Entidad certificadora: NEPSI
Protección: Ex ia IIC T6 Ga/GbExplosion ProtectionInglés , Chino -
Deltabar S
Código de producto: PMD75-, PMD70-, FMD78-, FMD77-, FMD76-
Región: Europe (ATEX)
Entidad certificadora: KEMA
Categoría: II 1 D, II 1 G
Protección: Ex ia IIC T6 Ga/GbExplosion ProtectionInglés -
Deltabar S
Código de producto: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Región: Germany
Entidad certificadora: DIBt
Número de certificado: Z-65.11-384Overfill PreventionAlemán -
Product Family: Deltabar S
Código de producto: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Región: International
Entidad certificadora: Fieldbus Foundation
Versión de software: DEVICE REV. 06, DD-ITK 5.01Fieldbus ConformanceInglés -
Product Family: Deltabar S
Código de producto: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Región: International
Entidad certificadora: PI, PROFIBUS International
Versión de software: PROFILE 3.02Fieldbus ConformanceInglés -
Product Family: Deltabar S
Código de producto: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Región: International
Entidad certificadora: Fieldbus Foundation
Versión de software: DEVICE REV. 06, DD-ITK 5.20Fieldbus ConformanceInglés -
Product Family: Deltabar S
Código de producto: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Región: International
Entidad certificadora: Fieldbus Foundation
Versión de software: DEVICE REV. 07, DD-ITK 6.10Fieldbus ConformanceInglés -
Deltabar S
Código de producto: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Región: Canada (CRN)
Entidad certificadora: CRNPressure EquipmentInglés
Accesorios / Piezas de repuesto
-
-
Nr 13 Order code 52022418
Push button housing, PA/FF
Consists of: push button, cover + screws. Usage: external operation, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 13 Order code 52022419
Push button housing, HART, version 1
Consists of: push button, cover + screws. Colour light grey. Usage: external operation, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 13 Order code 52024110
Push button housing, HART, version 2
Consists of: push button, cover + screws. Colour dark grey. Usage: external operation, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.
-
-
-
Order code 71111056
Housing filter VA,EPDM,F15/31/T14/17,1pc
Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
Order code 71219639
Housing filter VA, VMQ, F15, T17, 1 pc.
Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
-
-
Nr 15 Order code 52020760
Cable gland M20, gasket
Consists of: cable gland M20. O-ring 18.72x2.62 VMQ. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 15 Order code 52020761
Cable entry G1/2, gasket, adapter
Consists of: gasket 18.72x2.51 NBR. Adapter M20 > G1/2. O-ring 18.77x1.78 NBR. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 15 Order code 52020762
Plug 2/7-pole, HAN7D, gasket
Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Nr 15 Order code 52020763
Plug 3-pole, M12, gasket
Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 21 Order code 52020429
Sealing EPDM, F30/31/34, T14/15, 5 pcs.
Consists of: 5x O-ring 75.87x2.62, EPDM, PTFE, FDA. Usage: housing F30/F31/F34, T14/T15.
-
Nr 21 Order code 71206971
Sealing set FVQM, T14.5 pcs.
Consists of: 5x O-ring 75.87x2.62 FVMQ. Usage: housing T14, FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 20 Order code 52020432
Cover T14/T15 Alu, gasket
Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 52028310
Cover T14 316L, Ex d, EPDM
Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71002774
Cover T17 316L, gasket
Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71002810
Cover T17 316L, sight glass, gasket
Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.
-
Nr 20 Order code 71002811
Cover T17 316L, sight glass PC, gasket
Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.
-
Nr 20 Order code 71206965
Cover T14 316L, Ex d, FVMQ
Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.
-
Nr 20 Order code 71206968
Cover T14 316L, Ex d, sight glass, FVMQ
Material: 316L. Sight glass: mineral glass,coated. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71245249
Cover T14/T15 Alu,Exd,sight glass,gasket
Material: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71245250
Cover T14 316L, Ex d, sight glass, EPDM
Material: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 25 Order code 52020432
Cover T14/T15 Alu, gasket
Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 52028310
Cover T14 316L, Ex d, EPDM
Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 71002774
Cover T17 316L, gasket
Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 71206965
Cover T14 316L, Ex d, FVMQ
Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.
-
-
-
Nr 30 Order code 52024111
Electronics HART Ex, ext. p. b., v2.0
4-20mA, version 2.0. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 52024400
Electronics HART Ex, v2.0
4-20mA, version 2.0. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71026358
Electronics HART Ex, v2.10
4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71026359
Electronics HART Ex, ext. p. b., v2.10
4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71196092
Electronic HART Ex, v2.11
4-20mA, version 02.11.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71196093
Electronics HART Ex, ext. p. b., v2.11
4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
-
-
Order code 52026762
Upgrade electronics HART Ex, v2.1
Consists of: electronics HART Ex, version 2.1. Push button on electronics. Display housing. Usage: conversion electronics 1.0 > 2.1, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Order code 52026763
Upgrade electr. HART Ex,ext.push b.,v2.1
Consists of: electronics HART Ex, version 2.1. Push button external. Push button, housing HART version 2. Display housing. Usage: conversion electronics 1.0 > 2.1, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 30 Order code 71071824
Electronics PA, HW02.00, SW4.0
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071825
Electronics PA, ext. p.b., HW02.00,SW4.0
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071826
Electronics FF, HW2.00, SW3.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071827
Electronics FF, ext. p.b., HW2.00,SW3.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214057
Electronics PA, Ex, HW2.00, SW3.00
PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214064
Electronics PA, ext. p.b.,HW2.00, SW3.00
PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214066
Electronics FF, ext. p.b.,HW2.00, SW2.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214069
Electronics FF, HW2.00, SW2.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214890
Electronics FF, ext. p.b.,HW2.00, SW4.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.
-
Nr 30 Order code 71214892
Electronics FF, HW2.00, SW4.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.
-
Nr 30 Order code 71224775
Electronics PA, HW02.00, SW4.01
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71224776
Electronics PA, ext.p. b.,HW02.00,SW4.01
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 31 Order code 52027785
HistoROM / M-DAT, 16K
Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 35 Order code 52027691
Terminal 2-pole, RFI, FF, Ex
RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028475
Terminal 2-pole, RFI, PA, OVP, Ex
Overvoltage protection, RFI-filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028476
Terminal 2-pole, RFI, FF, OVP, Ex
Overvoltage protection, RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71121574
Terminal 2-pole, RFI, PA, Ex
RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for TIIS.
-
Nr 35 Order code 71191892
Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd
RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71191894
Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd
Overvoltage protection, RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 40 Order code 71002865
Display module VU340, Cbar/Dbar/Dpilot S
Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.
-
-
-
Order code 71043886
Cable PE, L=2m/80inch, separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71043888
Cable PE, L=5m/200inch, separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71043889
Cable PE, L=10m/400inch,separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71070738
Cable FEP, L=5m/200inch,separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 52024609
Mounting set Deltabar S, 7/16-20UNF
Screws 7/16-20UNF, stainless steel. Material: 316L. Usage: wall/pipe mounting 2", FMD77/FMD78, PMD75.
-
-
Predecesor