Introduzca por lo menos 2 caracteres para iniciar la búsqueda.
  • Historial

Proline Promag P 10
Electromagnetic flowmeter

Picture of electromagnetic flowmeter Proline Promag P 10 for basic process applications ©Endress+Hauser

Proline Promag P 10 for basic process applications

Picture of electromagnetic flowmeter Proline Promag P 10 for basic hazardous process applications ©Endress+Hauser

Proline Promag P 10 for basic process applications also in hazardous areas

Picture of electromagnetic flowmeter Proline Promag P 10 as a remote version ©Endress+Hauser

Proline Promag P 10 with remote transmitter and lap-joint flanges for basic process applications

Proline 10 – uncompromisingly simple

The Electromagnetic Flow Measuring Principle

Flowmeter for basic process applications with easy-to-use operation concept

Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. With its straightforward hard- and software design, Promag P 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology ensures safe processes.

  • Simple products

  • Easy to select, install and operate

Excelencia técnica

Simplicidad

  • Productos estándar

  • Seguros, resistentes y con poco mantenimiento

Excelencia técnica

Simplicidad

  • Productos de alta gama

  • Altamente funcionales y prácticos

Excelencia técnica

Simplicidad

  • Productos especializados

  • Diseñados para aplicaciones exigentes

Excelencia técnica

Simplicidad

Variable

Gamas FLEX Excelencia técnica Simplicidad
  • F
  • L
  • E
  • X

Gama Fundamental

Satisfaga sus necesidades básicas de medición

Excelencia técnica
Simplicidad
  • F
  • L
  • E
  • X

Gama Lean

Maneje los principales procesos fácilmente

Excelencia técnica
Simplicidad
  • F
  • L
  • E
  • X

Gama Extended

Optimice sus procesos con tecnologías innovadoras

Excelencia técnica
Simplicidad
  • F
  • L
  • E
  • X

Gama Xpert

Domine las aplicaciones más exigentes

Excelencia técnica
Simplicidad

Variable

  • Resumen de especificaciones

    • Error de medición máx.

      Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)

    • Rango de medición

      4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)

    • Rango de temperatura del medio

      Liner material PFA: –20 to +150 °C (–4 to +302 °F)
      Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

    • Máx. presión de proceso

      PN 40, Class 300, 20K

    • Materiales húmedos

      Liner: PFA; PTFE
      Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium

Selección rápida

Elija entre nuestras opciones recomendadas
Precio de venta
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

o

Configuración individual

Continúe seleccionando entre todas las opciones posibles
  • Ventajas

    • Diverse applications – wide variety of wetted materials

    • Energy-saving flow measurement – no pressure loss due to cross section constriction

    • Maintenance-free – no moving parts

    • Optimum usability – operation with mobile devices and SmartBlue app or display...

  • Ámbito de aplicación

    • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.

    • Dedicated to chemical and process applications with corrosive liquids.

    Device properties

    • Nominal diameter: max. DN 600 (24")

    • All common Ex approvals

    • Liner made of PTFE...

Características y especificaciones

Atrás

Details

  • Measuring principle

    Electromagnético

  • Título del producto

    Flowmeter for basic process applications with easy-to-use operation concept.
    Dedicated to chemical and process applications with corrosive liquids.

  • Características del sensor

    Diverse applications – wide variety of wetted materials. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts.
    Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA.

  • Características del transmisor

    Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
    System integration with HART, Modbus RS485. Flexible operation with app and optional display.

  • Rango de diámetro nominal

    DN 15 to 600 (½ to 24")

  • Materiales húmedos

    Liner: PFA; PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium

  • Variables medidas

    Volume flow, conductivity, mass flow

  • Error de medición máx.

    Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)

  • Rango de medición

    4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)

  • Máx. presión de proceso

    PN 40, Class 300, 20K

  • Rango de temperatura del medio

    Liner material PFA: –20 to +150 °C (–4 to +302 °F)
    Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

  • Rango de temperatura ambiente

    Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Material de carcaza del sensor

    DN 15 to 300 (½ to 12""): AlSi10Mg, coated
    DN 350 to 600 (14 to 24""): Carbon steel with protective varnish

  • Material de la cubierta del transmisor

    AlSi10Mg, coated

  • Grado de protección

    Standard: IP66/67, Type 4X enclosure

  • Pantalla/Operación

    2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible

  • Salidas

    4-20 mA HART (active/passive), Pulse/frequency/switch output
    Modbus RS485, 4-20 mA

  • Comunicación digital

    HART, MODBUS RS485

  • Suministro de energía

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Aprobaciones para áreas peligrosas

    ATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, JPN

  • Aprobaciones y certificados metrológicos

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Certificados y aprobaciones de presión

    PED, CRN

  • Certificados del material

    3.1 material

  • Aprobaciones higiénicas y certificados

    Driking water approvals: ACS; NSF61

Documentos / Manuales / Software

Accesorios / Piezas de repuesto

Nr
Order code
Specification
  • 38
    • Nr 38 Order code 71505739

      Kit S+T-DAT Promag 10, Non-haz/Exd/Z2

      Electronic storage module unprogrammed Usage: Promag 10. Consists of: S+T-DAT.

  • 33
  • 46
  • 33
    • Nr 33 Order code XPD0062-

      ISEM, enhanced, HART, nEx/Z2/Exd

      Usage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00.

    • Nr 33 Order code XPD0063-

      ISEM, enhanced, Modbus, nEx/Z2/Exd

      Usage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00.

  • 45
  • 44
    • Nr 44 Order code 71323264

      Kit connection board,Promag D/P/W,10/500

      Usage: Promag P 10 Ex, D/W 10 Non-haz, Promag P/W 500 Ex, Sensor connection housing. Consists of: connection board, cover to connection board.

  • 30
    • Nr 30 Order code XPD0080-

      HART, 24VDC, nEx, Alu, 10

      Electronic module E401. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0081-

      HART, 100-230VAC, nEx, Alu, 10

      Electronic module E403. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0082-

      HART, 100-230VAC/24VDC, nEx, Alu, 10

      Electronic module E408. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0083-

      HART, 100-230VAC/24VDC, Exd/Z2, Alu, 10

      Electronic module E404. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0084-

      Mbus,100-230VAC/24VDC, nEx/Exd/Z2,Alu,10

      Electronic module E411. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

  • 50
  • 21
    • Nr 21 Order code 71505748

      Kit cover, blind ,Alu,Non-haz/ Z2/ Div.2

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: cover blind Alu, O-Ring 110,70x3,53 HNBR.

  • 20
    • Nr 20 Order code 71505749

      Kit cover, glass,Alu,N-haz/Z2/Div.2/Exde

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: cover sight glass Alu, O-Ring 110,70x3,53 HNBR.

    • Nr 20 Order code 71505750

      Kit cover, sight glass, Alu, 10, Exd

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: cover sight glass Alu, O-Ring 110,70x3,53 HNBR.

  • 70
    • Nr 70 Order code 71505752

      Kit cover gasket, glass/blind, Alu, 10

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: 10x O-Ring 110,70x3,53 HNBR.

  • 23
    • Nr 23 Order code 71323038

      Kit cover, wall mount, Alu, Ex

      Usage: Promag 10, Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.

  • 75
    • Nr 75 Order code 71323042

      Kit cover gasket, wall mount, Ex

      Usage: Promag 10, Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu/cast, connection compartment. Consists of: 10x O-Ring 88,50x3,53 HNBR.

  • 24
    • Nr 24 Order code 71228796

      Kit cover, remote, Alu

      Usage: Promag 10/500, Promag/Promass/Prosonic Flow/t-mass 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

  • 73
    • Nr 73 Order code 71228798

      Kit housing gaskets, remote, Alu

      Usage: Promag 10/500, Promag 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor L/P/W, O-Ring 29,87x1,78 HNBR for sensor plug.

  • 72
    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

  • 71
    • Nr 71 Order code 71505753

      Kit interface gaskets, Alu, Promag 10

      Usage: Promag 10, transmitter housing/sensor or transmitter housing/wall mount. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface, 5x O-Ring 29,87x1,78 HNBR for for sensor plug.

  • 13
    • Nr 13 Order code 71276494

      Kit securing clamp, screw

      Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass, Promag/Promass 500, Promag 10, Promag/Promass/Prosonic Flow/t-mass 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover clamp, screw M4x16.

  • 87

Descargas