Introduzca por lo menos 2 caracteres para iniciar la búsqueda.
  • Historial

TAF12D
High temperature TC thermometer

TAF12D
High temperature TC thermometer ©Endress+Hauser

Applicable for ceramic baking ovens, brickworks, porcelain production and glass industries

Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell and the internal sheath made from ceramic materials protects from mechanical and chemical damages in the process and increases the life span of the sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

Selección rápida

Elija entre nuestras opciones recomendadas
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

o

Configuración individual

Continúe seleccionando entre todas las opciones posibles
  • Ventajas

    • Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance

    • Long term stable measurement due to sensor protection with non-porous materials

    • Flexible product selection by modular design

    • Optimized life cycle costs...

  • Ámbito de aplicación

    • The TAF12D are assemblies with double ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.

    • ...

Características y especificaciones

Atrás

Details

  • Measuring principle

    Termopar

  • Característica / Aplicación

    estilo métrico

    ensamble de temperatura modular

    sonda para alta temperatura (horno)

    conexión a proceso de la brida

    incl. Termo pozo doble de cerámica

  • termopozo / tubo de protección

    tubo de protección de cerámica y tubo interior

  • Inserto / sonda

    capilar cerámico, rígido

  • Diámetro exterior del tubo de protección

    14,00 mm ...15,00 mm

    (0,55''...0,59'')

  • Máx. longitud de inmersión bajo demanda

    hasta 3.500,00 mm (137,80'')

  • Protección de material tubo/termo pozo

    Cerámica (KER 530/KER 610/KER 710)

  • Conexión a proceso

    Brida ajustable

  • Forma de la Punta

    recto

  • Rango de temperatura de operación

    Tipo S:

    0 C ...1.600 C

    (32 F ...2.912 F)

    Tipo R:

    0 C ...1.600 C

    (32 F ...2.912 F)

    Tipo B:

    600 C ...1.700 C

    (1.112 F ...3.092 F)

  • Máx. presión de proceso (estática)

    a 20 °C: 1 bar (15 psi)

  • Precisión

    clase 2 de acuerdo a IEC 60584

  • Integración del transmisor de cabezal

    si (4 … 20 mA; HART; PROFIBUS PA; FUNDACIÓN FIELDBUS)

  • Certificación

    SIL (sólo transmisor)

Documentos / Manuales / Software

Accesorios / Piezas de repuesto

Nr
Order code
Specification
  • C
    • Nr C Order code 60000516

      Stop Flange adjustable,DIN EN 50446,23mm

      Maximum temperature 400 oC. Material cast iron. Counter flangeand gasket not provided. No gas-tight connection. Dimension: d2=23 mm, a=90 mm, c=70 mm. Clampable diameter from 21mm to 22mm.

    • Order code 60020836

      Compression fitting G 3/4", 22,5mm

      Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 21.3/22mm. Dimension: A=G 3/4", d=22.5 mm, Wr=41.

    • Order code 60021425

      Compression fitting G1 1/2", 22.5mm

      Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 21,3/22mm. Dimension: A=G 1 1/2", d=22,5 mm, Wr=55.

    • Order code 60021757

      Compression fitting G 1", 22,5mm

      Maximum temperature 350 oC. Maximum pressure 1 bar. Material 316Ti (1.4571). For Pipe diameters 21,3/22mm. Dimension: A=G 1", d=22,5 mm, Wr=41.

    • Order code 71182602

      Spare parts kit sealing TA30A/TA30D

      5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75

    • Order code 71044061

      Fixing kit cpl.TMT82/85/84 (european)

      2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector

  • B
    • Nr B Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code READWIN-

      Readwin 2000 Operation + Read. software